• Technip Norge AS

    Tekmar Subsea awarded multi-million pound contract by Technip Norge AS.

    Read news

  • Sapesco Libya

    Tekmar Subsea awarded pipeline repair clamp contract by Sapesco Libya.

    Read news

  • Acergy LARS

    Tekmar Subsea awarded Acergy contract to modify existing LARS.

    Read news

  • Walney Offshore Wind Farm

    Tekmar Energy awarded contract to supply Offshore Wind Farm Turbine cable protection systems to the Walney Offshore Wind Farm.

    Read news

  • Gravity Base Cable Protection System

    Tekmar Energy Supply Gravity Base Cable Protection System Prototype for Subsea Tidal Turbines.

    Read news

  • Tekmar Subsea seal hole in oil pipe wall

    Tekmar Subsea seal hole in oil pipe wall, saving 3,000 barrels of oil per day.

    Read news

  • Flare Stack Reinforcement

    Tekmar Subsea design and manufacture all equipment on a 21 day schedule, successfully install off the coast of Egypt.

    Read news

  • Teklink Cost Savings

    Teklink Achieves 70% Reduction in costs in offshore wind farm installations.

    Read news

Tekmar Group - News and Events

Flare Stack Reinforcement from Design to Installation in 21 Days
26th November 2009

 

The purpose of the project was to urgently reinforce the annular cavity in three subsea flare stacks before the stacks became unstable.

 

Tekmar Subsea were commissioned to design and manufacture all equipment on a 21 day schedule. Our service engineers then successfully installed the equipment of the coast of Egypt.

 

This was the first ROV performed flare stack reinforcement project completed in the region. The ROV was initially fitted with 1-off clamp and the subsea drilling machine. After latching onto the flare stack subsea a 2" diameter hole was remotely drilled. The ROV disengaged from the clamp leaving the system on the pipe and returned to surface for another clamp. This procedure was repeated until three clamps were installed and holes drilled on each each flare stack.

 

The subsea drilling machine was then removed from the ROV interface shelf and the grouting stabs fitted. This allowed the ROV to reattach to the installed clamps. Grout was then pumped into the annular cavity from the topside spread. Following completion of the grouting operation an isolation was activated and the ROV recovered.

 

Client benefits provided by solution

Long term reinforcement of severely corroded flare stacks ROV remote installation.

 

Project Responsibilities

• SAPESCO Installation contractor
• TEKMAR SUBSEA Equipment supplier